IONIA ESE Lightning Arrester
Design
- Non-Electronic ESE
- No use of battery or external power source
- 304L (Inox) Stainless Steel – suitable for any environmental conditions
- Remote Monitoring Facility
Testing
- Tested & certified for NF C 17-102 (2011) standard UNE 21186:2011 standard
- 219 kA (10/350 µs) Lightning Impulse Current Tested.
- △T = 78 μs – Early Streamer Emission Test
- CE Certified.
Suitable for various down conductors
| Protection radius as per NF C 17-102 (2011) | ||||
|---|---|---|---|---|
| Mast Height h (m) | Level I Very High | Level II High | Level III Medium | Level IV Standard |
| 2 | 38 | 42 | 46 | 50 |
| 3 | 58 | 63 | 69 | 75 |
| 4 | 77 | 84 | 93 | 101 |
| 5 | 96 | 105 | 116 | 126 |
| 6 | 97 | 105 | 116 | 127 |
| 10 | 97 | 106 | 118 | 128 |
| 15 | 98 | 107 | 120 | 131 |
| 100 | 114 | 129 | 148 | 165 |